We use cookies and other technologies on this website to enhance your user experience.
By clicking any link on this page you are giving your consent to our Privacy Policy and Cookies Policy.

ZELIO Wi-Fi TCP/Modbus 螢幕截圖

關於ZELIO Wi-Fi TCP/Modbus

對話的Wi-Fi與智能繼電器的Zelio +以太網模塊連接到接入點

ITA:

Questa applicazione consente di interfacciarsi con uno smart-relè Zelio provvisto del modulo Ethernet connesso a un Access-Point.

Una volta digitato l'indirizzo IP del modulo Ethernet dello Zelio e attivata la connessione è possibile

leggere i registri interni dello smart-relè, in particolare sia quelli "scrivibili" (denominati j1XT1, j2XT1, j3XT1 e j4XT1) 4x00016, 4x00017, 4x00018 e 4x00019 sia quelli solo "leggibili" (denominati o1XT1, o2XT1, o3XT1 e o4XT1) 4x00020, 4x00021, 4x00022 e 4x00023 (scritti dall'interno del programma dello Zelio in FBD)

I valori letti sono rappresentati in modalità:

UINT=> 16bits non segnati

INT=> 16bits segnati

HEXA=> esadecimale

BIN=> 16bits rappresentati in nibble (in gruppi di 4)

E' anche possibile, selezionando il registro relativo scrivere un valore settabile in modalità UINT oppure con 16 selettori uno per ciascuno dei bits componenti la variabile medesima in modalità BINARIA.

Sono stati implementati alcuni controlli sui campi indirizzo IP, selezione registro da scrivere e valore impostato in tale registro.

Lo stato della connessione è sempre disponibile in alto a destra dello schermo.

La visione del filmato facilita la comprensione della modalità operativa nell'uso dell'applicazione

ENG:

This application allows you to interface with a smart-relay Zelio provided Ethernet module connected to an access point.

After entering the IP address of the Ethernet module and the Zelio activated the connection is possible to read the internal registers of the smart-relay, in particular and those "writable" (called j1XT1, j2XT1, j3XT1 and j4XT1) 4x00016, 4x00017, 4x00018 and 4x00019 and those only "readable" (called O1XT1, o2XT1, o3XT1 and O4XT1) 4x00020 , 4x00021, 4x00022 and 4x00023 (written from within the program of Zelio in FBD).

The values are represented in the mode:

UINT => 16bits unsigned

INT => 16bits signed

HEXA => hexadecimal

BIN => 16bits represented in nibble (in groups of 4)

It is possible, by selecting the record to write a value (settable mode UINT) or with 16 switches one for each of the bits making up the same variable in BINARY mode.

Have been implemented some controls on the fields IP address, selection register to write and value set in this register.

The connection status is always available at the top right of the screen.

The vision of the video facilitates the understanding of the mode of operation in the use of the application

最新版本1.3更新日誌

Last updated on 2016年02月12日

ITA:
In questa ultima versione è stata introdotta la "retentività della comunicazione" fino a quando l’applicazione non viene chiusa.
In questo modo il dispositivo non entra più in stand-by finchè non si preme il pulsante di uscita.

ENG:
This latest version has been introduced the “keeping communication” until the application is closed.
In this way, the device does not go into standby mode (sleep state) until You press the exit button.

翻譯中...

更多應用信息

最新版本

請求 ZELIO Wi-Fi TCP/Modbus 更新 1.3

上傳者

لخضر محمد

系統要求

Android 1.6+

更多
訂閱APKPure
第一時間獲取熱門安卓遊戲應用的首發體驗,最新資訊和玩法教程。
不,謝謝
訂閱
訂閱成功!
您已訂閱APKPure。
訂閱APKPure
第一時間獲取熱門安卓遊戲應用的首發體驗,最新資訊和玩法教程。
不,謝謝
訂閱
成功!
您已訂閱我們的郵件通知。