We use cookies and other technologies on this website to enhance your user experience.
By clicking any link on this page you are giving your consent to our Privacy Policy and Cookies Policy.
Pipe Headloss Calculator Plus 圖標

1.5.2 by Transparent Blue


2013年08月13日

Pipe Headloss Calculator Plus 螢幕截圖

關於Pipe Headloss Calculator Plus

用於估計管道中的水頭損失

Pipe Headloss Calculator Plus app can be used for estimating frictional head loss in pipes. This app version compared to the free includes fittings and valves calculation and selection of the pipe material.

The total pressure loss in the system results from the combined losses due to friction in length of pipe and friction losses due to valves, fittings, and other components. The first are "major losses" associated with energy loss per length of pipe, and seconds are "minor losses" associated with bends, fittings, valves, etc.

The factors that determine friction losses in pipe are:

The velocity of the water: As velocity increases, pressure losses increase. Velocity is directly related to flow rate.

The size (inside diameter) of the pipe: Smaller pipe causes a greater proportion of the water to be in contact with the pipe, which creates friction. Pipe size also affects velocity. Given a constant flow rate, decreasing pipe size increases the water’s velocity, which increases friction.

The roughness of the inside of the pipe: Pipe inside wall roughness is rated by a C factor, which can be selected depending on material of pipe. The lower the C value, the rougher the inside and the more pressure loss due to friction.

The length of the pipe: The friction losses are cumulative as the water travels through the length of pipe. The greater the distance, the greater the friction losses will be.

The friction losses for, elbows, and tees can also be selected. The friction losses in fittings such as couplings, elbows, tees, valves and other elements play a role. Friction loss from these components must be taken into account when calculating friction losses for each section of pipe.

Calculation of friction factor is based on the Hazen-Williams equation. Local resistances factor K for valves and some fittings (tees, elbows, pipes contraction and enlargement), can be found in app itself.

Example:

Calculate pressure losses in a pumping of 10 l / s. The diameter of the suction and discharge is 100 mm or 4 ". We have the following items on the Suction: 1 foot valve, 1 gate valve , 1 elbow 90, 1 contraction to 3" to entering the pump. In the discharge we have: 1 expansion, 2 elbow 90,

a check valve, 1 gate valve. The total pipe length is 10 meters in diameter of 100 mm. Must be calculated the pressure losses for the given flow.

最新版本1.5.2更新日誌

Last updated on 2013年08月13日

Minor bug fixes and improvements. Install or update to the newest version to check it out!

翻譯中...

更多應用信息

最新版本

請求 Pipe Headloss Calculator Plus 更新 1.5.2

系統要求

1.6

更多
訂閱APKPure
第一時間獲取熱門安卓遊戲應用的首發體驗,最新資訊和玩法教程。
不,謝謝
訂閱
訂閱成功!
您已訂閱APKPure。
訂閱APKPure
第一時間獲取熱門安卓遊戲應用的首發體驗,最新資訊和玩法教程。
不,謝謝
訂閱
成功!
您已訂閱我們的郵件通知。