আমরা আপনার ব্যবহারকারীর অভিজ্ঞতা বাড়ানোর জন্য এই ওয়েবসাইটে কুকি এবং অন্যান্য প্রযুক্তি ব্যবহার করি।
এই পেজে কোনো লিঙ্কে ক্লিক করে আপনি আমাদের Privacy Policy and কুকি নীতিতে আপনার সম্মতি দিচ্ছেন।
ঠিক আছে আমি সম্মতি জানাচ্ছি আরো জানুন

Pipe Headloss Calculator Plus স্ক্রিনশট

Pipe Headloss Calculator Plus সম্পর্কে

পাইপে জল জলের ক্ষতি অনুমান করার জন্য

Pipe Headloss Calculator Plus app can be used for estimating frictional head loss in pipes. This app version compared to the free includes fittings and valves calculation and selection of the pipe material.

The total pressure loss in the system results from the combined losses due to friction in length of pipe and friction losses due to valves, fittings, and other components. The first are "major losses" associated with energy loss per length of pipe, and seconds are "minor losses" associated with bends, fittings, valves, etc.

The factors that determine friction losses in pipe are:

The velocity of the water: As velocity increases, pressure losses increase. Velocity is directly related to flow rate.

The size (inside diameter) of the pipe: Smaller pipe causes a greater proportion of the water to be in contact with the pipe, which creates friction. Pipe size also affects velocity. Given a constant flow rate, decreasing pipe size increases the water’s velocity, which increases friction.

The roughness of the inside of the pipe: Pipe inside wall roughness is rated by a C factor, which can be selected depending on material of pipe. The lower the C value, the rougher the inside and the more pressure loss due to friction.

The length of the pipe: The friction losses are cumulative as the water travels through the length of pipe. The greater the distance, the greater the friction losses will be.

The friction losses for, elbows, and tees can also be selected. The friction losses in fittings such as couplings, elbows, tees, valves and other elements play a role. Friction loss from these components must be taken into account when calculating friction losses for each section of pipe.

Calculation of friction factor is based on the Hazen-Williams equation. Local resistances factor K for valves and some fittings (tees, elbows, pipes contraction and enlargement), can be found in app itself.

Example:

Calculate pressure losses in a pumping of 10 l / s. The diameter of the suction and discharge is 100 mm or 4 ". We have the following items on the Suction: 1 foot valve, 1 gate valve , 1 elbow 90, 1 contraction to 3" to entering the pump. In the discharge we have: 1 expansion, 2 elbow 90,

a check valve, 1 gate valve. The total pipe length is 10 meters in diameter of 100 mm. Must be calculated the pressure losses for the given flow.

সর্বশেষ সংস্করণ 1.5.2 এ নতুন কী

Last updated on Aug 13, 2013

Minor bug fixes and improvements. Install or update to the newest version to check it out!

অনুবাদ লোড হচ্ছে...

অতিরিক্ত অ্যাপ তথ্য

সাম্প্রতিক সংস্করণ

Pipe Headloss Calculator Plus আপডেটের অনুরোধ করুন 1.5.2

Android প্রয়োজন

1.6

আরো দেখান
APKPure সাবস্ক্রাইব করুন
সেরা অ্যান্ড্রয়েড গেমস এবং অ্যাপ্লিকেশনগুলির প্রাথমিক রিলিজ, সংবাদ এবং গাইডগুলিতে অ্যাক্সেস পাওয়ার জন্য প্রথম হন।
না ধন্যবাদ
নিবন্ধন করুন
সফলভাবে সাবস্ক্রাইব!
আপনি এখন এপকপুরে সাবস্ক্রাইব করেছেন।
APKPure সাবস্ক্রাইব করুন
সেরা অ্যান্ড্রয়েড গেমস এবং অ্যাপ্লিকেশনগুলির প্রাথমিক রিলিজ, সংবাদ এবং গাইডগুলিতে অ্যাক্সেস পাওয়ার জন্য প্রথম হন।
না ধন্যবাদ
নিবন্ধন করুন
সাফল্য!
আপনি এখন আমাদের নিউজলেটারে সাবস্ক্রাইব করেছেন।